Detalhes do produto:
Lugar de origem: China
Marca: SUNNY
Certificação: CE,ISO9001
Número do modelo: SN-RD6-W
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 1 peça
Preço: $20~100
Detalhes da embalagem: pacote de exportação padrão
Tempo de entrega: 7~15 dias
Termos de pagamento: Western Union, T/T, L/C, Paypal
Habilidade da fonte: mês de 1000 PCes

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

descrição
Nome: Relé de monitoramento de tensão de 3 fases tipo: Relé de monitoramento de tensão de 3 fases
Tensão: 200 ... 500 VCA Modelo: Relé de monitoramento de tensão de 3 fases
Produto: Relé de monitoramento de tensão de 3 fases Frequência nominal: 50/60Hz±1Hz
Material de contato: Agsno Temperatura: -20...+60℃
Nível de proteção: IP40 Escala da exposição de tensão: 150 ... 500 Vca
Tamanho: 80×43×54mm

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay

 

Main features

 

◼︎ One unit can monitor voltage imbalance, phase sequence, and under phase of three-phase 3-wire or 4-wire power supplies

◼︎ Switch settings for 3-phase or 3-wire or 4-wire power supplies

◼︎ 1 SPDT output relay, 6A at 250VAC (resistive load)

◼︎ 1 unit supports power specifications from around the world (switchable)

◼︎ Convenient monitoring of relay alarm status using LED indicators

 

Data sheet

 

Rated voltage 200 ... 500VAC
Rated frequency 50/60Hz±1Hz
Contact type 2NO / 1NC
Contact material AgSnO
Contact rating 5A 280VAC / 8A 30VDC
Contact life 2×10
Temperature -20 ... +60℃
Phase imbalance
≤10%
Insulation voltage 2.5KV / 1mn / 1mA / 50Hz
Protection level IP40
Voltage action setting time 0.1 ... 20s
Phase loss and error time 0.1 ... 20s
Overcurrent setting value
-
Indicator Display
Voltage display range 150 ... 500V AC
Maximum Counting 999999
Maximum timing capacity
9999 hours and 59 minutes
Timing input signal Active24V,110V,220V or 380V
Data retention time 18 years
Size 80 × 43 × 54 mm

 

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 0

 

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 1

50/60Hz±1Hz Rated Frequency For Elevator 3 Phases Voltage Monitoring Relay 2

 

FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.

Contacto
SHANGHAI SUNNY ELEVATOR CO.,LTD

Pessoa de Contato: Mr. Wei CHEN

Telefone: +86-13661864321

Fax: 86-021-59168286

Envie sua pergunta diretamente para nós (0 / 3000)